[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Publication Statistics::
List of Reviewers::
Social Networks::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Search published articles ::
Showing 4 results for amiri

Eng. Karim Amiri, Dr. Rasool Kazemzadeh,
Volume 5, Issue 1 (Vol.5, No.1 2019)
Abstract

The development of renewable energy sources, distributed generation, energy storage and nonlinear controllable loads in modern distribution networks has led to the consideration of the state estimation in intelligent and active distribution networks. The performance of the Energy Management Central's distribution network depends on the results of the state estimation. In this paper, two-stage estimation with the network reduction process is proposed. The number of distribution network meter is low, so obtaining accurate initial information from network conditions improves performance state estimation. The initial state estimation with the network reduction process to obtain accurate initial data is performed. The initial data are used as a measure to improve the performance of secondary estimation. This method solves the problem of scarcity of accurate measurements and improves the accuracy of the state estimation in distribution network. The results of the proposed methodology are demonstrated on the 69 nodes of IEEE  standard distribution network.


Farhad Amiri, Mohammad Hassan Moradi,
Volume 7, Issue 1 (9-2020)
Abstract

In this paper, a new output feedback control method was used based on a linear matrix inequality to control the angular position of AC servo motor shaft. The proposed control method does not need to measure all of the AC servo motor statuses; it only uses the output feedback and is robust against the uncertain servo motor parameters and the disturbances applied to it. The proposed control method was compared in several scenarios with a Standard Internal Model Control-Sliding Mode Control (SIMC-SMC) method, 2-Degree-of-Freedom Internal Model Control-Sliding Mode Controller (2DOF-IMC-SMC) method, 2-Degree-of-Freedom Internal Model Control-Proportional-Integral-Derivative (2DOF-IMC-PID) method, Standard Internal Model Control-Proportional-Derivatives (SIMC-PD) method, and Internal Model Control-Proportional-Integral-Derivative-Extended State Observer (IMC-PID-ESO) method. The simulation results show that the proposed controller has desirable performance against disturbances and uncertain parameters of the AC servo motor compared with other mentioned controllers. This method relative to other controllers decreased the error of tracking the angular position of the servo motor to 30% .The simulation was performed in the Matlab Software. 
Farhad Amiri, Mohammad Hassan Moradi,
Volume 9, Issue 2 (3-2023)
Abstract

In an islanded microgrid, power electronic converters are used to exchange power, and these converters have very low inertia, thus compromising the frequency stability of the microgrid. Virtual inertia control is used to improve the frequency stability of an islanded microgrid. The derivative control technique is usually used to implement virtual inertia control in the microgrid. Factors such as disturbance and uncertainty of parameters of the islanded microgrid compromise the performance of virtual inertia control and may cause system frequency instability. Therefore, the virtual inertia control structure, a complementary controller is needed that can weaken the effect of disturbance on the microgrid as much as possible and be resistant to the uncertainty of parameters of the microgrid. In this paper, a robust control method is used in a virtual inertia control structure that uses system output feedback. The proposed method is expressed based on linear matrix inequality and is proved based on the Lyapunov criterion. Among the advantages of the proposed method is the attenuation of disturbance, resistance to the uncertainty of parameters of the microgrid, and increasing the degree of freedom to control the system in this method. The results of the proposed method to improve the performance of virtual inertia control in several different scenarios by considering the uncertainty of parameters of the two-zone microgrid and disturbances on the microgrid are compared with several methods and the effectiveness of the proposed method in terms of improving frequency stability is shown.

 
Farhad Amiri, Mohammad Hassan Moradi,
Volume 10, Issue 1 (3-2023)
Abstract

The issue of frequency control is very important in the power system. The presence of wind turbine in the power system makes frequency control challenging. In order to improve the frequency control of the power system in the presence of wind turbine, in this paper, a new control method is designed. In this method, the coordinated control of load-frequency control (LFC) system and superconducting magnetic energy storage (SMES) has been discussed using PD-FOPID cascade controller. The PD member in this type of controller responds to the frequency changes of the power system faster and also the FOPID member has a favorable performance against the uncertainty of the system parameters and disturbances. In this paper, the problem of owl search algorithm is solved. Considering that the owl search algorithm may get stuck in the local optimum. In this paper, solutions are presented to solve this problem of the owl search algorithm, which is called the developed owl search algorithm, and in order to improve the performance of the PD-FOPID controller, the developed owl search algorithm is used to optimally adjust its parameters. . The proposed control method with several methods including: Load frequency control (LFC) and superconducting magnetic energy storage (SMES) based on the robust controller, LFC and SMES based on the MSA-PID controller, LFC based on the MSA-PID controller with SMES and LFC based on the MSA-PID controller without SMES has been compared in four scenarios and the results show the superiority of the proposed method over the other mentioned methods. Is. The proposed method is resistant to load disturbances, disturbances caused by wind turbines, and uncertainty related to system parameters.

 

Page 1 from 1     

سامانه های غیرخطی در مهندسی برق Journal of Nonlinear Systems in Electrical Engineering
نشریه سامانه‌های غیرخطی در مهندسی برق در خصوص اصول اخلاقی انتشار مقاله، از توصیه‌های «کمیته بین‌المللی اخلاق نشر» موسوم به COPE و «منشور و موازین اخلاق پژوهش» مصوب معاونت پژوهش و فناوری وزارت علوم، تحقیقات و فناوری تبعیت می‌کند.
Persian site map - English site map - Created in 0.12 seconds with 28 queries by YEKTAWEB 4642